QB-F Automotive Wire On 3F

Nov 06, 2026

Leave a message

QB-F Automotive Wire for 3F (National Standard QC/T 730 Series, FEP Fluoroplastic Insulation)

QB-F belongs to the QB series thin-walled low-voltage automotive single line, which is the highest temperature resistant fluoroplastic model after QB-B/C/D. F is not separately defined in the standard text and is an extended development model by industry manufacturers. The insulation is FEP (perfluoroethylene propylene)

 

✅ Core parameters
-Rated voltage: 60V DC/25V AC (automotive low-voltage system, consistent with AVSS/FLRY)
-Temperature resistance range: -40 ℃ to+200 ℃ (fixed installation)
-Conductor: Stranded multi strand tinned copper (GB/T3956 Class 5/6 flexible conductor)
-Insulation: FEP (Teflon FEP) thin-walled extrusion, flame retardant, oil resistant, chemical resistant, hydrolysis resistant, low smoke, non adhesive, extremely strong aging resistance
-Section range: 0.13-120 mm ², monochrome/two-color identification
-Execution basis: QC/T 730-2005 Automotive Thin Wall Low Voltage Wire Frame, Additional Fluoroplastic Material Specification, Simultaneously Meets ISO6722 Flame Retardant Requirements

 

         Tin plated/bare copper conductor, single/bundle twisted structure

news-458-87

                      Polyfluoroethylene propylene insulation outer cover

 

✅ Physical properties

a.Low temperature winding: After being placed in a freezer at -40℃± 2℃ for a minimum of 4 hours without cracking, and then subjected to a 1kV withstand voltage test for 1 minute without breakdown.
b.Short term aging: Conduct a 240 hour aging test in an oven at a test temperature of 225℃± 4℃, conduct a winding test in a -25℃± 2℃ freezer without cracking, and then undergo a 1-minute 1kV withstand voltage test without breakdown.
c.Heat shrinkage: Place horizontally in an oven at a test temperature of 150℃± 3℃ for no less than 15 minutes. After the test, any end of the insulation will shrink by no more than 2mm.
d.Thermal overload: Perform a 6-hour thermal overload in a 250 ℃± 4 ℃ oven, then conduct a winding experiment without cracking, and undergo a 1-minute 1kV withstand voltage test without breakdown.
e.Flame retardant: After removing the flame, it will extinguish on its own within 70 seconds, and at least 50mm of unburned insulation should be retained at the top of the sample.
--Wires with a nominal cross-sectional area not exceeding 2.5mm ² shall be removed after 15 seconds of flame exposure;
--For wires with a nominal cross-sectional area greater than 2.5mm ², remove the flame after applying it to the wire for 30 seconds.

 

✅ QB series horizontal comparison
- QB-B:PVC, 105℃ | Conventional instrument and interior wiring harness (benchmarking AVSS)
-QB-C: XLPE cross-linked PE, 125℃ | Cabin medium temperature zone
- QB-D:XLPE/XLPO, 150℃ | Cabin high temperature, new energy low pressure auxiliary line
-QB-F: FEP fluoroplastic, 200℃ | extremely high temperature

Send Inquiry